Quant 3D Q150 Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Imprimer et scanner Quant 3D Q150. Quant 3D Q150 User guide [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 122
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
USER GUIDE
For Research Use Only. Not for use in diagnostic procedures.
QuantStudio
®
3D Digital PCR System
for use with:
QuantStudio
®
3D Digital PCR Instrument
ProFlex
2x Flat PCR System or Dual Flat Block GeneAmp
®
PCR System 9700
QuantStudio
®
3D Digital PCR Master Mix
QuantStudio
®
3D Digital PCR 20K Chip
QuantStudio
®
3D Digital PCR Chip Loader
Catalog Numbers A25581 or A25606
Publication Number MAN0007720
Revision C.0
Vue de la page 0
1 2 3 4 5 6 ... 121 122

Résumé du contenu

Page 1 - 3D Digital PCR System

USER GUIDEFor Research Use Only. Not for use in diagnostic procedures.QuantStudio® 3D Digital PCR Systemfor use with:QuantStudio® 3D Digital PCR Instr

Page 2

The QuantStudio® 3D AnalysisSuite™ Software is a web-based application that isverified for use with the following operating systems and internet brows

Page 3 - Contents

d.If your selected wireless hotspot is secure, enter the required authenticationinformation (user name/password), then touch OK.If connecting your ins

Page 4

c.If you elected to assign a static IP to the instrument, touch the followingfields and enter the:• IP Address – Enter the static IP address for the i

Page 5 - (Optional)

e.Touch , then configure the Windows Internet Naming Service (WINS)settings:• Windows Domain – Enter the domain name of the WINS server.• WINS Server

Page 6

7.In the Network Complete screen, touch OK, then touch to return to the MainMenu.After the instrument has successfully connected to the network, the

Page 7

3.In the Edit Destinations screen, touch Add to add a data destination.Note: To edit an existing destination, touch the name of the destination.4.In

Page 8 - About this guide

• LAN data destination fields:– Target Name – Enter a name to identify the LAN data destination.Note: The target name appears within the Destination

Page 9 - Instrument software

Parts and Materials How to order from the website ... 106 General-use materials and consumables ...

Page 10 - Instrument consumables

Description SourceReaction tubes, DNase/RNase-free, non-stick orlow-binding: 0.5-mL or 1.5-mLFisher Scientific (Cat. no.13-864-253 or 13-864-254) or M

Page 11 - Getting Started

Cat. no.Description4485813 QuantStudio® 3D Digital PCR UV Kit• AAAA Batteries for UV-Curing Stylus (6)• UV-Activated Chip Sealant Syringe and tips• UV

Page 12 - Instrument filters

Specifications and Layout Component dimensions and weights ... 109 QuantStudio® 3D Digital PCR Instrument layout and c

Page 13 - Operating the instrument

Getting Started About the QuantStudio® 3D Digital PCR System ... 11 Operating the instrument ...

Page 14 - Prepare the QuantStudio

QuantStudio® 3D Digital PCR Instrument layout and connectionsThe QuantStudio® 3D Digital PCR Instrument and the ProFlex™ 2x Flat PCR System(or Dual Fl

Page 15 - Plan the

Electrical specificationsWARNING! For safety, the power outlet used for powering the instrumentmust be accessible at all times. In case of emergency,

Page 16 - Choose additional

Environmental requirementsEnsure that the installation room is maintained under correct environmentalconditions.Condition Acceptable RangeInstallation

Page 17 - Instrument

Network requirementsThe QuantStudio® 3D Digital PCR Instrument supports IPv4 TCP/IP communicationand provides two methods for integrating the device i

Page 18

SafetyWARNING! GENERAL SAFETY. Using this product in a manner not specifiedin the user documentation may result in personal injury or damage to thein

Page 19

Symbol English FrançaisDo not dispose of this product inunsorted municipal wasteCAUTION! To minimizenegative environmentalimpact from disposal ofelec

Page 20 - IMPORTANT! The QuantStudio

Safety alerts on this instrumentAdditional text may be used with one of the symbols described above when morespecific information is needed to avoid e

Page 21 - The QuantStudio

Safety information for instruments not manufactured by ThermoFisher ScientificSome of the accessories provided as part of the instrument system are no

Page 22

CAUTION! Cleaning and Decontamination. Use only the cleaning anddecontamination methods specified in the manufacturer's user documentation.It is

Page 23 - Install the thermal

ReferenceDescriptionAS/NZS 2064Limits and Methods of Measurement ofElectromagnetic DisturbanceCharacteristics of Industrial, Scientific, andMedical (I

Page 24 - IMPORTANT! The ProFlex

The QuantStudio® 3D Digital PCR System collects raw fluorescence data from theQuantStudio® 3D Digital PCR 20K Chip following PCR amplification.The ins

Page 25

Biological hazard safetyWARNING! Potential Biohazard. Depending on the samples used on thisinstrument, the surface may be considered a biohazard. Use

Page 26 - PCR System

Documentation and supportCustomer and technical supportVisit www.lifetechnologies.com/support for the latest in services and support,including:• World

Page 27 - CAUTION HOT

For support visit lifetechnologies.com/support or email [email protected] February 2015

Page 28

Operating the instrumentThe QuantStudio® 3D Digital PCR System can be used to perform experiments usingcompatible Applied Biosystems® reagent kits and

Page 29 - PCR System 9700

Prepare the QuantStudio® 3D Digital PCR System for useYou can install the QuantStudio® 3D Digital PCR System within one hour. Theinstallation requires

Page 30 - IMPORTANT! The GeneAmp

When planning the placement of the QuantStudio® 3D Digital PCR Systemcomponents, give special consideration to the design and organization of thelabor

Page 31 - IMPORTANT! If the GeneAmp

Choose the instrument locationsPlacement of the QuantStudio® 3D Digital PCR Instrument and ProFlex™ 2x Flat PCRSystem (or Dual Flat Block GeneAmp® PCR

Page 32

1.Plan the organization of your laboratory. Identify the locations of all stations inthe QuantStudio® 3D Digital PCR Instrument workflow, including:•

Page 33

c.Remove the QuantStudio® 3D Instrument from the package and set it on aclean level surface, then remove the protective cover.d.Inspect the QuantStudi

Page 34 - 3D Instrument to a network

6.If you intend to connect your instrument to a network, prepare the physicalnetwork connection:IMPORTANT! Connecting the instrument to a network is

Page 35 - Software

The information in this guide is subject to change without notice.DISCLAIMERLIFE TECHNOLOGIES CORPORATION AND/OR ITS AFFILIATE(S) DISCLAIM ALL WARRANT

Page 36 - Reactions

7.Install the QuantStudio® 3D Instrument:a.Connect the power cord to the QuantStudio® 3D Instrument, press thepower switch to the ON position, then wa

Page 37 - Determine the

d.In the Choose Connection Type screen, select the appropriate connection:Connection ActionWired Touch LAN, then wait for the instrument to connect

Page 38

e.In the Network Complete screen, touch OK.f.In the Configuration screen, touch Edit to change the instrument settings.g.In the Edit Configuration scr

Page 39 - Prepare the

h.In the Configuration screen, touch OK to accept the instrumentconfiguration.The QuantStudio® 3D Instrument is ready to use when the touchscreendispl

Page 40

c.Remove the ProFlex™ PCR System Base Module from the package and set iton a clean, level surface, then remove the protective cover.5 cm (2 in)20 cm (

Page 41 - X0300036

b.While holding the riser in place with one hand, insert the thin end of thecable tie through the opening at the base of the foot. When the end is vis

Page 42

e.Using the second cable tie, repeat steps a-d to secure the riser at the otherend of the foot.dbc45°a6.Using scissors, remove the excess material fro

Page 43 - Load and seal the

8.Unpack and install the sample block module:a.Open the package containing the sample block module and inspect it fordamage caused during transportati

Page 44

10.Set up the ProFlex™ System:a.Open the package containing the Chip Adapters and install them.Note: Each Chip Adapter includes a set of four alignme

Page 45 - IMPORTANT! Press the

11.For optimal results, create a new method from the existing 3D template suppliedwith the ProFlex™ System and verify the pre-defined method for therm

Page 46

ContentsAbout this guide ... 8Revision history ...

Page 47

c.Remove the GeneAmp® PCR System 9700 Base Module from the packageand set it on a clean level surface, then remove the protective cover.5 cm (2 in)20

Page 48

e.Inspect the Dual Flat Block Module for damage caused duringtransportation.If the instrument is damaged, note the location and appearance of thedamag

Page 49

d.When the GeneAmp® PCR System 9700 displays the main menu, confirmthat the version number displayed on the screen is 3.12 or greater. If theversion n

Page 50 - Load chips manually

b.Press the D/M/Y or Y/M/D soft keys until the format you want for thecurrent date displays in the Date field.c.Use the numeric keys to enter the valu

Page 51 - Digital PCR 20K

If you... Then...do not want to protect your methods press Accept (F1) again.want to protect your methods see the GeneAmp® PCR System 9700Base Module

Page 52

Connect the QuantStudio® 3D AnalysisSuite™ SoftwareYou can connect to the QuantStudio® 3D AnalysisSuite™ Software before or after youinstall the Quant

Page 53 - IMPORTANT! Allow the

Prepare Samples and LoadReactions Prepare the DNA samples ... 36 Prepare the digital PCR reactions ...

Page 54

Quantitation methodsBefore performing digital PCR experiments, consider quantifying the amount ofgDNA or cDNA in each sample.We recommend the followin

Page 55

If the target copy number per genome is unknown, say for a locus of unknown copiesper genome or RNA of unknown expression level, we recommend that you

Page 56

In this procedure, you will prepare the PCR reactions for the samples that you intendto load to QuantStudio® 3D Digital PCR 20K Chip. The volumes of t

Page 57

CHAPTER 2 Prepare Samples and Load Reactions ... 36Prepare the DNA samples ...

Page 58 - Perform the PCR

4.In a 0.5- or 1.5-mL low-binding reaction tube, prepare sufficient PCR reactionmix for your samples. Prepare the reaction mix at room temperature and

Page 59

To ensure the proper processing and analysis of your loaded Digital PCR 20K Chip,handle them according to the following guidelines:•Always wear powder

Page 60 - Version: 3.12

Load the chips using the Chip LoaderThe following procedure explains how to load QuantStudio® 3D Digital PCR 20KChips automatically using a QuantStudi

Page 61 - Materials

Recovering from a Chip Loader errorPerform the following steps if the QuantStudio® 3D Digital PCR Chip Loader statuslight flashes red, indicating that

Page 62 - Guidelines for

IMPORTANT! Confirm that the tip is locked firmly in place before proceeding.Keep out of sunlight32141Plunger2UV-Activated Chip Sealant Syringe3Chip

Page 63

4.Load the PCR reaction onto a Digital PCR 20K Chip:a.Open the QuantStudio® 3D Digital PCR 20K Chip package, then gentlygrasp the chip by its sides an

Page 64 - Unload the

c.Remove the red protective film from a QuantStudio® 3D Digital PCR ChipCase Lid, press the Lid Nest button ( ), carefully place the Chip Case Lidinto

Page 65

e.Press the black loading button on the Chip Loader to load the Digital PCR20K Chip.IMPORTANT! Before pressing the loading button, confirm that the S

Page 66 - Analyze the Prepared Chips

5.Rotate the Chip Loader arm so that the Chip Case Lid solidly contacts the DigitalPCR 20K Chip, firmly press down for 15 seconds to ensure a tight se

Page 67 - Analysis workflow

7.Seal the Chip Case using Chip Sealant:a.Hold the syringe tip just above (or in slight contact with the inside wall) ofthe fill port of the sealed Ch

Page 68 - About the

CHAPTER 4 Analyze the Prepared Chips ... 66Using the QuantStudio® 3D Digital PCR Instrument ...

Page 69 - Analyze the chips

c.When the light powers off (approximately ³15 seconds), remove the chipand place it on a clean, dry, lint-free surface.IMPORTANT! Remove the Digital

Page 70

• Immersion Fluid Tip•UV-Activated Chip Sealant Syringe• UV-Curing Stylus for Chip Sealant• UV-Curing Stylus Stand• Isopropanol• Gloves, powder-free,

Page 71

IMPORTANT! Confirm that the tip is locked firmly in place before proceeding.Keep out of sunlight32141Plunger2UV-Activated Chip Sealant Syringe3Chip

Page 72

4.Remove the following consumables from their packaging and place them on aclean, dry, lint-free surface:• QuantStudio® 3D Digital PCR Chip Case Lid•

Page 73 - Analyzing the data

c.While holding the Sample Loading Blade at a 70-80° angle relative to theheated block so that the port faces up, place the edge of the blade at the e

Page 74 - About the results

7.Seal the Digital PCR 20K Chip:a.Remove the red protective film from the QuantStudio® 3D Digital PCR ChipCase Lid, then carefully place it onto the p

Page 75 - About the data

9.Seal the Chip Case using Chip Sealant:a.Hold the syringe tip just above (or in slight contact with the inside wall) ofthe fill port of the sealed Ch

Page 76 - Transfer the

10.Visually inspect the sealed Digital PCR 20K Chip for potential problems:• Leaks – Confirm that no Immersion Fluid is leaking from the fill port ora

Page 77 - Using the QuantStudio

Perform the PCR Choosing a thermal cycler ... 58 Thermal cycle the Digital PCR 20K Chips ...

Page 78

Before running each batch of Digital PCR 20K Chips, perform the following to ensureefficient thermal cycling:•Confirm that the following parts are ins

Page 79 - Troubleshooting

APPENDIX B Networking ... 95Networking overview ...

Page 80

• Confirm the thermal cycler is running the correct firmware version number tothermal cycle Digital PCR 20K Chips:– ProFlex™ 2x Flat PCR System – The

Page 81

Table 5 GeneAmp® PCR System 9700 PCR MethodPCR ProtocolRunSpeedReactionVolumeStage 1 Stage 2 Stage 396.0°C 60.0°C 98.0°C 60.0°C 10.0°C[1]Standard 2

Page 82 - (QuantStudio

To ensure the proper function of your loaded Digital PCR 20K Chips, handle the ChipCases according to the following guidelines:•Always wear powder-fre

Page 83 - IMPORTANT! Condensation

3.Load the QuantStudio® 3D Digital PCR 20K Chips into the thermal cycler:a.Place the sealed Digital PCR 20K Chips onto the sample block so that the fi

Page 84

4.Use the thermal cycler to select and start the pre-programmed run for the DigitalPCR 20K Chips. See the ProFlex™ PCR System User Guide (Pub. no. MAN

Page 85

3.Remove the Chip Adapters from the thermal cycler sample block and place themon a clean, dry surface. Remove the Digital PCR 20K Chips from the ChipA

Page 86 - Maintenance

Analyze the Prepared Chips Using the QuantStudio® 3D Digital PCR Instrument ... 66 Analyze the chips ...

Page 87 - Clean the chip tray

The following figure shows the workflow for running a single QuantStudio® 3DDigital PCR 20K Chip on the QuantStudio® 3D Digital PCR Instrument.StartqL

Page 88

The QuantStudio® 3D Digital PCR Instrument features a simple interface for readingthermal cycled QuantStudio® 3D Digital PCR 20K Chips.65431 21Network

Page 89 - 3D Instrument for service

Analyze the chipsThe following materials are required to image loaded Digital PCR 20K Chips on theQuantStudio® 3D Digital PCR System.• Prepared Digita

Page 90 - Replace the instrument fuses

Documentation and support ... 121Customer and technical support ...

Page 91 - Replace the fuses

2.(Optional) Enter a prefix to apply to each experiment (.eds) file name:a.From the Main Menu of the QuantStudio® 3D Instrument, touch , thentouch In

Page 92 - Update the

The touchscreen displays the USB drive icon ( ) when the QuantStudio® 3DInstrument has mounted the USB drive.2.Open the chip tray and load the Digital

Page 93 - View the instrument log

3.In the instrument touchscreen, wait for the QuantStudio® 3D Instrument todetect and image the chip.IMPORTANT! Do not open the chip tray or remove t

Page 94

5.After reviewing the results of the run, open the chip tray and remove the chip (orremove the USB drive, if present) to close the results screen.If t

Page 95 - Networking

The QuantStudio® 3D Digital PCR Instrument displays a summary of the imagingdata after each successful run. For each QuantStudio® 3D Digital PCR 20K C

Page 96 - Network setup

Data quality flags generated and displayed by the software are a measure of theoverall chip quality, based on well quality thresholds and other data a

Page 97 - Required network

If a data transfer is unsuccessful, you can use the QuantStudio® 3D Instrument RunHistory screen to transfer experiment files to a USB drive for manua

Page 98 - Instrument to a

The Run History screen displays the data transfer status next to each file in theinstrument memory:• Pass – The instrument successfully transferred th

Page 99

When deployed in cloud configuration, the AnalysisSuite™ Software is accessed as aweb-based application that can be run using any compatible web brows

Page 100

TroubleshootingTroubleshooting chip images using the Chip ViewThe following table summarizes some of the more common problems that can affectimaging o

Page 101

About this guideCAUTION! ABBREVIATED SAFETY ALERTS. Hazard symbols and hazardtypes specified in procedures may be abbreviated in this document. For t

Page 102

Observation Possible Cause ActionA bubble was present in theSample Loading Blade when itwas used to apply the PCRreaction to the Digital PCR 20KChip.I

Page 103 - Create a network

Observation Possible Cause Action• The Digital PCR 20K Chipleaked during thermalcycling or imaging.• A large bubble was presentin the chip (insufficie

Page 104

Observation Possible Cause ActionChip was not completely coveredwith Immersion Fluidimmediately after loading (whilestill on the chip loader or heated

Page 105

Observation Possible Cause ActionCondensation may have beenpresent on the Digital PCR 20KChip during imaging.IMPORTANT! Condensationmay not be visibl

Page 106 - Parts and Materials

Observation Possible Cause ActionExcess template was loaded ontothe chip.In the QuantStudio® 3DAnalysisSuite™ Software, checkthe copies per reaction a

Page 107

Observation Possible Cause ActionToo much sample was left inloading blade.Ensure that you are loading only14.5 µL of reaction mix into theloading blad

Page 108

Maintenance Cleaning the chip tray and sample block ... 86 Configure the instrument settings ...

Page 109 - Specifications and Layout

CAUTION! PHYSICAL INJURY HAZARD. Do not remove the covers to theQuantStudio® 3D Instrument or thermal cycler. There are no components insidethe instr

Page 110 - Instrument clearances

Configure the instrument settingsAfter you install the QuantStudio® 3D Digital PCR Instrument, you can configure theinstrument settings for your regio

Page 111 - Electrical specifications

Use this procedure to manually configure the time zone, date, and time settings foryour instrument.Note: If connected to a network, the QuantStudio®

Page 112 - Environmental requirements

PrerequisitesThis guide also assumes that you have:• Knowledge of techniques for handling and preparing samples for PCR.• A general understanding of d

Page 113 - Network requirements

To return your instrument for service:1.Contact your local customer care center or technical support group (see “Customer and technical support“ on pa

Page 114 - Symbols on this instrument

CAUTION! FIRE HAZARD. For continued protection against the risk of fire,replace fuses only with listed and certified fuses of the same type and ratin

Page 115 - Conformity

1.Download the firmware update:a.Go to www.lifetechnologies.com/supportb.Go to Instrument Management (you will need to log in if not alreadylogged in

Page 116 - Location of safety

Calibrate the touchscreenCalibrate the instrument touchscreen periodically as part of the routine maintenanceof your instrument, if you observe a decr

Page 117 - Instrument safety

4.(Optional) Export the system log to a USB drive:a.Plug the drive into the USB port on the front of the QuantStudio® 3DInstrument.b.In the Instrument

Page 118 - 3D Digital PCR Chip Loader

Networking Networking overview ... 95 Connect the instrument to the network ...

Page 119 - Chemical safety

The wireless dongle sold for use with the QuantStudio® 3D Digital PCR Instrumentcan be installed to an internal USB port behind the rear panel to enab

Page 120 - Biological hazard safety

ConnectionMaterialsWired CAT6 Ethernet cable of sufficient length with RJ45 connectors (for a1000Mbit/s network connection or a CAT5 for a 100Mbit/s c

Page 121 - Documentation and support

1.Prepare the physical connection to the network:Connection ActionWired1. Power on the QuantStudio® 3D Instrument.2. Connect one end of a standard cat

Page 122 - 4 February 2015

3.Choose the appropriate option:If connecting your instrument to a… ActionWired network that supports DHCP Network setup is complete.Note: The QuantS

Commentaires sur ces manuels

Pas de commentaire